| No | Finding Date | HAC | Description | Status | Action |
|---|---|---|---|---|---|
| 721 | 2026-06-01 | L62-YA1 | Material yard reject sundul chute, garuk manual supaya tidak blocking done | Done | View |
| 722 | 2026-05-24 | 332-EW1 | Tangga akses menuju lantai 332,EW1 kusam dan kotor | Done | View |
| 723 | 2026-05-24 | 332-EW1 | Lampu penerangan sekitar 332-EW di penuhi sarang laba2 membuat pencahayaan pada malam hari kurang maksimal | Done | View |
| 724 | 2026-05-24 | 332-EW1 | Papan peringatan resiko terjatuh kotor | Done | View |
| 725 | 2026-05-30 | L92-CX1 | Cleaning tube filter suction udara L92-CX1 karena KW conveying kompressor agak drop 82-85 dibandingkan normalnya 95-97 | Done | View |
| 726 | 2026-05-30 | 462-KL1 | Cleaning inlet kiln slidingwall | Done | View |
| 727 | 2026-05-30 | L21-RE1 | Smoldering diatas magic box reclaimer coal | Done | View |
| 728 | 2026-05-30 | 462-LN1 | lampu penerangan area kiln cooler ER5, PF burner-calciner mati Action : resetting timer lampu | Done | View |
| 729 | 2026-05-30 | 462-KL1 | After pemakaian projek water sprayer kiln shell M5 | Done | View |
| 730 | 2026-05-30 | 462-KL1 KILN SHELL | nozel water sprayer kiln shell rusak Action : replace nozle done | Done | View |
| 731 | 2026-05-30 | 442-AB1. NO 8A | Redspot mengitari nozel ---> action fabrikasi boxstone | Done | View |
| 732 | 2026-05-30 | 452-TV4 | Fault torque motor ---> action manual engkol di gearbox motor dari opening 15% ke 75% | Done | View |
| 733 | 2026-05-29 | 442-PH1 | monitoirng area after hot work di preheater lt. 2 TQ2 | Done | View |
| 734 | 2026-05-29 | 462-KL1 | lampu penenrangan area Kiln TQ2 masih belum nyala saat kondisi sudah gelap, dinyalakan manual | Done | View |
| 735 | 2026-05-29 | L21-RE1 | penyemnprotan smoldering di magic box reclaimer coal | Done | View |
| 736 | 2026-05-29 | D33-PV1 | rutin drain PV | Done | View |
| 737 | 2026-05-29 | 482-PF1 | Kiln stop, PF Finecoal burner stuck, Action adjust gap | Done | View |
| 738 | 2026-05-25 | 61B - PGC | Instrumen kotor membuat kontrol cepat rusak | Done | View |
| 739 | 2026-05-22 | 562 - MD1 | Cooling fan motor kotor banyak material, menyumbat aliran udara membuat motor panas. | Done | View |
| 740 | 2026-05-20 | 562 - MD1 | Box tempat tabung asiteline banyak sampah | Done | View |
| 741 | 2026-05-12 | 532-LQ1.L1 | Socket sensor pecah | Done | View |
| 742 | 2026-05-25 | 361-MD1 | Cleaning area | Done | View |
| 743 | 2026-05-25 | 361-MD1 | Cleaning | Done | View |
| 744 | 2026-05-25 | 361-MD1 | Cleaning area | Done | View |
| 745 | 2026-05-25 | 361-MD1 | Cleaning area done | Done | View |
| 746 | 2026-05-11 | 361-MD1 | Cleaning area | Done | View |
| 747 | 2026-05-11 | 361-MD1 | Cleaning area | Done | View |
| 748 | 2026-05-11 | 361-MD1 | Cleaning | Done | View |
| 749 | 2026-05-29 | V61-SH1 | Area kotor | Done | View |
| 750 | 2026-05-29 | Preheater TQ1 lantai 3 | Area kotor | Done | View |
| 751 | 2026-05-29 | TQ.461-KL1.Lantai 1,5 | #Quick Fix Draft tinggi -14 saat produksi type-5,Akumulasi penempelan material di check hole numpuk banyak | Done | View |
| 752 | 2026-05-29 | TQ.461-KL1.Lantai 1,75 | #Quick Fix Checkhole lantai 1.75 sisi Utara Buntu tertutup Material | Done | View |
| 753 | 2026-05-29 | 481-BU1 | Checkhole burner terlepas, unsafe condition krn berpotensi false air dan blow back burner | Done | View |
| 754 | 2026-05-29 | TQ.461-KL1.Lantai 1,75 | # Quick Fix Checkhole lantai 1,75 Banyak penempelan material | Done | View |
| 755 | 2026-05-29 | TQ.461-KL1.Lantai 1,5 | #Quick Fix Akumulasi material coating di sliding wall sisi Utara numpuk | Done | View |
| 756 | 2026-05-29 | TQ.461-KL1.P1 | #Quick Fix Penunjukan Sensor draft P1 Buntu | Done | View |
| 757 | 2026-05-25 | L61 - FN2 | Area kotor banyak debu coal | Done | View |
| 758 | 2026-05-25 | L61 - FN2 | Area kotor | Done | View |
| 759 | 2026-05-25 | L61 - FN2 | Area banyak ceceran coal | Done | View |
| 760 | 2026-05-25 | L61 - FN2 | Area kotor dan berdebu | Done | View |
| 761 | 2026-05-25 | L61 - FN2 | Area sekitar L61-FN2 kotor | Done | View |
| 762 | 2026-05-22 | l01- FT1 | Jatuhan material dijalan depan ido room | Done | View |
| 763 | 2026-05-22 | l01- FT1 | Ceceran material depan ido room, cleaning | Done | View |
| 764 | 2026-05-25 | L01-FT1 Tangki IDO Kiln | Depan ido room kotor penuh dengan jatuhan material dijalan, cleaning(quick fiks) | Done | View |
| 765 | 2026-05-27 | L03-FP3 | Pressure gauge broken, ganti dengan yang baru(quick fiks) | Done | View |
| 766 | 2026-05-27 | L01-FT1 Tangki IDO Kiln | Drain RCO prepare heating up(quick fiks) | Done | View |
| 767 | 2026-05-28 | L01-FP1&2 | Filter clogging, cleaning(quick fiks) | Done | View |
| 768 | 2026-05-28 | L03-FP 3 sd 5 | Filter clogging, cleaning(quick fiks) | Done | View |